Combi systems
Best for 1–3 bathroom homes with good mains pressure. No tank, no cylinder, instant hot water. Most efficient for typical Scunthorpe semis and terraces.
Full Central Heating · Scunthorpe & Humber
New boiler, new radiators, new pipework, new controls — sized properly with a room-by-room heat-loss calc and commissioned to manufacturer benchmark. One quote, one team, one warranty.
★★★★★10-year parts & labour warranty on Ideal, Baxi & Worcester · Building Notification included · Free quotes in 24–48 hours.
Service overview
A full central heating install isn't a bigger boiler swap — it's a system design. Pipe sizes, flow rates, radiator outputs, control zoning and balancing all have to work together, or you end up with cold rooms and a high gas bill in a brand-new system.
Complete new central heating: new boiler (combi, system or regular), new radiators sized to room heat-loss, new pipework (copper or MLCP), modern controls (Hive / Nest / Worcester), system filter, scale reducer and inhibitor charge. Plus full commissioning and Building Notification.
Homeowners in Scunthorpe, Brigg, Hull, Grimsby and the wider Humber region who are extending, refurbishing, switching from electric or storage heating, or simply replacing a tired old system that's never quite worked right.
Major renovation; loft conversion or extension that needs new circuits; conversion from storage heaters to wet central heating; old system that's repeatedly failing and isn't worth patching; or moving from a back-boiler / regular system to a modern combi or unvented setup.
The difference between an install that runs at 95% efficiency and one running at 75% is design. Heat-loss-calculated rads, correctly sized pipes, zoned controls and a balanced flow rate save 20%+ off the gas bill — every year, forever.
What goes wrong
We're often the second installer in. The first one fitted a new boiler onto old pipework and called it a new system. Here's what we find:
8kW rads being fed off 15mm pipe — physically can't deliver the heat. We size pipework to the actual flow rate, in 22mm or 28mm where needed.
Bedroom rads sized off 'looks about right' instead of room heat-loss. Cold bedrooms in January are a sizing problem, not a boiler problem.
One thermostat in the hallway controlling the whole house wastes meaningful energy. Modern installs are zoned by floor or by room as a default.
Lock-shield valves left fully open, so the nearest rad takes all the flow and the furthest stays cold. Every install we do is balanced room-by-room with a digital flowmeter.
Copper to plastic with no insert, hidden push-fit elbows behind tiles, plastic on the flow side of the boiler. We use the right material for each section and document where every joint is.
Manufacturer benchmarking now requires both on a new install. Skip them and you've voided the 10-year warranty on day one.
Our process
From first survey to final handover, end-to-end accountability.
Full room-by-room heat-loss calculation using building dimensions, glazing and insulation values. Determines boiler size, rad sizes and pipe sizes.
Drawn out: zones, controls, rad layout, pipe routes. Choices explained: combi vs system, copper vs MLCP, 1 zone vs 2.
Itemised quote covering boiler, rads, valves, controls, pipework, decoration touch-up and timing. Three options where useful.
Old system stripped, new pipework run (lifted boards relayed clean), rads hung, boiler mounted, controls wired, system filter and scale reducer fitted.
Chemically flushed, filled with treated water and Sentinel X100 inhibitor, gas-rate set, flue gases analysed, controls programmed.
Every rad balanced individually. Customer walk-through of controls. Benchmark book, Gas Safe certificate and Building Notification logged.
Benefits
Correctly sized, balanced and zoned systems run more efficiently than poorly-designed equivalents — meaningful savings every winter.
Every rad sized to its room. No cold bedroom, no over-cooked living room.
No banging pipes, no kettling, no air locks — because the system was bled, balanced and treated properly.
Full extended manufacturer warranty registered on completion.
Gas Safe certificate, Building Notification, benchmark book, manufacturer registration — everything a buyer's solicitor will ask for.
Same engineer surveys, installs, commissions and answers the phone for the next decade.
Recent work
A few recent full central heating installation jobs completed across North Lincolnshire.


In detail
Every property is different. The right system depends on water demand, mains pressure, space, and how you actually live in the house.
Best for 1–3 bathroom homes with good mains pressure. No tank, no cylinder, instant hot water. Most efficient for typical Scunthorpe semis and terraces.
Best for larger homes, multiple bathrooms running simultaneously, families. Mains-pressure hot water at every tap. We're G3 certified for unvented installs — full design detail on our unvented page.
Retained where the property has weak mains, a low-loss header or specialist requirements. Modern condensing regular boilers with insulated cylinders and good controls remain efficient.
Copper for visible runs and connections to fixed appliances — soldered or press-fit. MLCP (multi-layer plastic composite) for first-fix in floors and walls where flexibility and speed matter. Both fully BS-EN compliant when installed correctly.
Minimum spec: programmable room thermostat with weather/load compensation, TRVs on every rad except the room with the stat. Better: Hive Multizone or equivalent — two zones (upstairs/downstairs) cuts a typical bill by ~15%.
Stelrad, Myson, Quinn Round Top — sized to the room heat-loss. Vertical and designer rads where space dictates. Towel rails on dual-fuel valves so they work in summer too.
Wet UFH on the ground floor with rads upstairs is the most comfortable layout we install. Manifold, blending valve and weather compensation integrated into the boiler controls — covered fully on our underfloor heating page.
If we're keeping any existing radiators, the system gets power-flushed before the new boiler goes on — protecting the 10-year warranty and removing sludge that would otherwise re-circulate.
Frequently asked
Can't see your question? Ring Azim directly on 07576 593045.
Highly variable by property. A 3-bed semi in Scunthorpe converting from storage heaters typically lands £7,500–£11,000 supplied and fitted. A larger 4–5 bed Hull property with two zones, an unvented cylinder and 12 radiators sits £11,000–£16,000. Every quote is fixed in writing.
Typically 4–7 working days depending on size and access. We plan around when you'll be in the house and which rooms you can do without.
We lift carpets and boards carefully and relay them clean. Floor protection down throughout, dust sheets over furniture, every off-cut and bit of packaging removed at the end of each day.
Yes — up to 10 years on the boiler (manufacturer, subject to product and registration), 5 years on the rads, and a 5-year workmanship warranty on the install itself from us, in writing.
Yes — every install is notified to Gas Safe within 30 days; certificate posted to you. Required for sale of the property.
Yes — we'll quote phased installs (e.g. boiler + rads now, controls upgrade later) where budget makes sense. We'll always tell you what we'd prioritise.
All redundant materials removed, scrapped responsibly, and site swept on completion.
Yes — full central heating installs across Hull, Grimsby and Doncaster on the same fixed-price model as our North Lincs work.
Related services
Next step
Free heat-loss survey, fixed written quote, full Building Notification handled. Free quotes across North Lincolnshire.